Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 128
Filtrar
1.
Surg Innov ; 31(3): 256-262, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38565982

RESUMO

OBJECTIVE: In this case report, the auxiliary role of deep learning and 3-dimensional printing technology in the perioperative period was discussed to guide transcatheter aortic valve replacement and coronary stent implantation simultaneously. CASE PRESENTATION: A 68-year-old man had shortness of breath and chest tightness, accompanied by paroxysmal nocturnal dyspnea, 2 weeks before presenting at our hospital. Echocardiography results obtained in the outpatient department showed severe aortic stenosis combined with regurgitation and pleural effusion. The patient was first treated with closed thoracic drainage. After 800 mL of pleural effusion was collected, the patient's symptoms were relieved and he was admitted to the hospital. Preoperative transthoracic echocardiography showed severe bicuspid aortic valve stenosis combined with calcification and aortic regurgitation (mean pressure gradient, 42 mmHg). Preoperative computed tomography results showed a type I bicuspid aortic valve with severe eccentric calcification. The leaflet could be seen from the left coronary artery plane, which indicated an extremely high possibility of coronary obstruction. After preoperative imaging assessment, deep learning and 3-dimensional printing technology were used for evaluation and simulation. Guided transcatheter aortic valve replacement and a coronary stent implant were completed successfully. Postoperative digital subtraction angiography showed that the bioprosthesis and the chimney coronary stent were in ideal positions. Transesophageal echocardiography showed normal morphology without paravalvular regurgitation. CONCLUSION: The perioperative guidance of deep learning and 3-dimensional printing are of great help for surgical strategy formulation in patients with severe bicuspid aortic valve stenosis with calcification and high-risk coronary obstruction.


Assuntos
Estenose da Valva Aórtica , Aprendizado Profundo , Impressão Tridimensional , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Masculino , Idoso , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Stents , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/anormalidades , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem
3.
J Clin Med ; 13(5)2024 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-38592142

RESUMO

Transcatheter aortic valve replacement (TAVR) has proven to be a safe, effective, and less invasive approach to aortic valve replacement in patients with aortic stenosis. In patients who underwent prior aortic valve replacement, transcatheter and surgical bioprosthetic valve dysfunction may occur as a result of structural deterioration or nonstructural causes such as prosthesis-patient mismatch (PPM) and paravalvular regurgitation. Valve-in-Valve (ViV) TAVR is a procedure that is being increasingly utilized for the replacement of failed transcatheter or surgical bioprosthetic aortic valves. Data regarding long-term outcomes are limited due to the recency of the procedure's approval, but available data regarding the short- and long-term outcomes of ViV TAVR are promising. Studies have shown a reduction in perioperative and 30-day mortality with ViV TAVR procedures compared to redo surgical repair of failed bioprosthetic aortic valves, but 1-year and 5-year mortality rates are more controversial and lack sufficient data. Despite the reduction in 30-day mortality, PPM and rates of coronary obstruction are higher in ViV TAVR as compared to both redo surgical valve repair and native TAVR procedures. New transcatheter heart valve designs and new procedural techniques have been developed to reduce the risk of PPM and coronary obstruction. Newer generation valves, new procedural techniques, and increased operator experience with ViV TAVR may improve patient outcomes; however, further studies are needed to better understand the safety, efficacy, and durability of ViV TAVR.

5.
JACC Cardiovasc Interv ; 17(6): 742-752, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38538170

RESUMO

BACKGROUND: Coronary obstruction (CO) is a potentially life-threatening complication of transcatheter aortic valve replacement (TAVR). Chimney stenting or leaflet laceration with transcatheter electrosurgery (Bioprosthetic or Native Aortic Scallop Intentional Laceration to Prevent Iatrogenic Coronary Artery Obstruction [BASILICA]) are 2 techniques developed to prevent CO. OBJECTIVES: The aim of the present study was to compare periprocedural and 1-year outcomes of chimney and BASILICA in TAVR patients at high risk of CO. METHODS: This multicenter observational registry enrolled consecutive TAVR patients at high risk of CO, undergoing either preventive chimney stenting or BASILICA. Clinical success was defined as successful performance of the chimney or BASILICA technique without clinically relevant ostial CO. The primary endpoint was major adverse cardiovascular events, a composite of death, myocardial infarction, stroke, or unplanned target lesion coronary revascularization at 1 year. RESULTS: A total of 168 patients were included: 71 (42.3%) received chimney stenting, and 97 (57.7%) underwent BASILICA. Patients undergoing BASILICA had higher preprocedural risk of CO, as indicated by lower sinotubular junction height (18.2 ± 4.8 mm vs 14.8 ± 3.4 mm; P < 0.001) and diameter (28.2 ± 4.5 vs 26.8 ± 3.4; P = 0.029). Rates of periprocedural complications were similar between the 2 groups. Clinical success was 97.2% and 96.9% in chimney and BASILICA, respectively (P = 0.92). At 1-year follow-up, the cumulative incidence of major adverse cardiovascular events was 18.7% (95% CI: 11%-30.6%) in the chimney group and 19.9% (95% CI: 12.1%-31.5%) in the BASILICA group (log-rank P = 0.848), whereas chimney was associated with a numerically higher cardiovascular mortality than BASILICA (6.7% vs 1.3%; log-rank P = 0.168). CONCLUSIONS: Chimney stenting and BASILICA effectively prevent TAVR-induced acute CO. Both techniques seem to have comparable acceptable periprocedural and 1-year outcomes.


Assuntos
Estenose da Valva Aórtica , Oclusão Coronária , Próteses Valvulares Cardíacas , Lacerações , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Lacerações/complicações , Lacerações/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Oclusão Coronária/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Desenho de Prótese
7.
Front Cardiovasc Med ; 11: 1334871, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38440208

RESUMO

Transcatheter aortic valve replacement (TAVR) has emerged as a viable treatment for aortic valve disease, including low-risk patients. However, as TAVR usage increases, concerns about long-term durability and the potential for addition interventions have arisen. Transcatheter aortic valve (TAV)-in-TAV procedures have shown promise in selected patients in numerous registries, offering a less morbid alternative to TAVR explantation. In this review, the authors aimed to comprehensively review the experience surrounding TAV-in-TAV, summarize available data, discuss pre-procedural planning, highlight associated challenges, emphasize the importance of coronary obstruction assessment and provide insights into the future of this technique.

8.
Eur J Cardiothorac Surg ; 65(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38366915

RESUMO

Delayed coronary obstruction is a rare complication occurring after transcatheter aortic valve replacement (TAVR). Although TAVR has become popular, in some cases, the therapeutic strategy should be carefully selected depending on the patient's anatomical and/or functional restrictions. We report a rare case of delayed coronary obstruction in which coronary obstruction was caused by thick endothelialization of the nitinol frame of the prosthetic valve. A 79-year-old female who had undergone TAVR 4 months before presented with mild chest pain and was admitted to our institution. Computed tomography and coronary angiography revealed that the space from the sinus of Valsalva to the nitinol frame was narrow and separated from the inside of the nitinol frame because of critical endothelialization. Therefore, an emergency surgical aortic valve replacement was performed. The patient had an uneventful postoperative course and was discharged 20 days postoperatively without any complications.


Assuntos
Estenose da Valva Aórtica , Oclusão Coronária , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Feminino , Humanos , Idoso , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Ligas , Substituição da Valva Aórtica Transcateter/efeitos adversos , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/etiologia , Oclusão Coronária/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Desenho de Prótese
10.
Am J Cardiol ; 211: 1-8, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-37884114

RESUMO

The number of patients who underwent transcatheter aortic valve implantation (TAVI) with the potential for reintervention is steadily increasing; however, there is a risk of sinus sequestration (SS) during a redo TAVI. The prevalence, predictors, and risk stratification of the risk for SS remain uncertain. We analyzed computed tomography acquired from 263 patients who underwent TAVI between 2021 and 2022: balloon-expandable valve (BEV) (71%) and self-expandable valve (SEV) (29%). Patients were considered at risk for SS if they met the following: (1) BEV frame > sinotubular junction (STJ) or SEV neocommissure greater than the STJ and (2) valve-to-STJ <2 mm. The risk of left, right, and any SS in 51%, 50%, and 65%, respectively, did not differ between BEV and SEV. The predictors of any SS were the height of the left and right coronary cusp (odds ratio [OR] 0.81 and 0.71, cutoff 18.6 and 19.2 mm, respectively) and STJ minus the annulus diameter (OR 0.65, cutoff 3.7 mm) in BEV, and STJ diameter (OR 0.47, cutoff 27.6 mm) in SEV. The number of predictors stratified the risk of any SS: low risk with BEV at 0 predictors (14% at risk of SS), intermediate risk at 1 predictor (65%), high risk at 2 or 3 predictors (81% and 95%), and low risk with SEV at 0 predictors (33%) versus high risk at 1 predictor (91%). In conclusion, 2/3 of patients who underwent TAVI were at risk of SS. The height of the coronary cusp and the STJ diameter were associated with and adequately stratified the risk of SS.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Prevalência , Valva Aórtica/cirurgia , Medição de Risco , Desenho de Prótese , Resultado do Tratamento
12.
JACC Case Rep ; 23: 101992, 2023 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-37954954

RESUMO

Coronary artery obstruction caused by sinus sequestration is well described after transcatheter aortic valve implantation in failed bioprosthetic valves, which usually occurs during or shortly after the transcatheter aortic valve implantation procedure. We report the presentation, management, and outcomes of 2 cases of very late sinus sequestration in native aortic annuli, which has not been described before to our knowledge. (Level of Difficulty: Advanced.).

13.
Catheter Cardiovasc Interv ; 102(7): 1393-1400, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37870111

RESUMO

Transcatheter aortic valve implantation (TAVI) has become a well-established treatment option for elderly patients with symptomatic severe aortic stenosis. Coronary artery anomalies are an infrequent finding and there have only been few anecdotal reports of patients with coronary anomalies treated with TAVI. We here present a comprehensive overview of existing reports in addition to an own case series to facilitate better understanding of this potentially challenging clinical scenario.


Assuntos
Estenose da Valva Aórtica , Cardiopatias Congênitas , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Vasos Coronários , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Resultado do Tratamento
14.
J Clin Med ; 12(14)2023 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-37510906

RESUMO

Within the last two decades, transcatheter aortic valve replacement (TAVR) has transformed the treatment strategy for symptomatic severe aortic stenosis (AS), representing a less invasive alternative to traditional open-chest surgery. With time, advances in device features, imaging planning, and implantation techniques have contributed to an improvement in safety as well as a reduction in procedural complications. This has led to the expansion of TAVR to lower-risk patients, where TAVR has shown favorable outcomes compared to surgical aortic valve replacement (SAVR). As TAVR expands to younger and lower-risk patients with longer life expectancies, the need for reintervention for failing transcatheter heart valves is expected to increase. Redo-TAVR has gained increasing relevance in the lifetime management of AS as one of the treatment strategies available for structural valve dysfunction (SVD). However, some issues are associated with this approach, including coronary re-access and the risk of coronary obstruction. In this review, we provide essential concepts to properly select candidates for Redo-TAVR, updated data on clinical outcomes and complication rates, and current gaps in evidence.

16.
JACC Cardiovasc Interv ; 16(16): 2021-2030, 2023 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-37480892

RESUMO

BACKGROUND: Preprocedural computed tomography (CT) workup with assessment of virtual transcatheter heart valve-to-coronary ostia (VTC) distance and transcatheter heart valve-to-sinus (VTS) distances is recommended to assess the risk of coronary obstruction following valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR). OBJECTIVES: The authors sought to investigate the agreement of predicted VTC and VTS distances and observed post-TAVR anatomy on CT and their relationship with transcatheter heart valve (THV) expansion and deployment conditions. METHODS: Fifty-one patients who underwent a balloon-expandable ViV procedure were included in this study. The expansion of the THV stent frame was evaluated at 4 levels: THV inflow, surgical heart valve (SHV) sewing ring, SHV outflow, and THV outflow. Assessment of the VTC/VTS distances was performed on the pre-TAVR CT, and THV-to-coronary ostia and THV-to-sinus distances were assessed on the post-TAVR CT. RESULTS: Following the ViV procedure, the THV stent frame flared toward the outflow but was generally underexpanded at all levels, particularly at the SHV sewing ring level. Postdilatation impacted the extent of THV expansion, resulting in greater expansion than nominal balloon filling at all 4 THV levels (P < 0.001). Observed THV-to-coronary ostia distances were systematically larger than predicted by the VTC distance (mean difference 1.25 ±1.28 mm) in patients with nominal balloon filling but systematically smaller in case of postdilatation (mean difference -0.45 ± 0.52 mm). A similar relationship was observed between VTS and THV-to-sinus distance measurements. CONCLUSIONS: With nominal balloon filling, VTC and VTS distances underestimate postprocedural distances due to THV frame underexpansion. However, postdilatation may lead to distances smaller than predicted due to THV overexpansion at the outflow level.


Assuntos
Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Coração , Catéteres , Tomografia Computadorizada por Raios X
18.
Cureus ; 15(6): e40514, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37461763

RESUMO

Delayed coronary obstruction (DCO) occurs when there is obstruction of the coronary ostia following a transcatheter aortic valvular implantation (TAVI). It is an uncommon but serious complication that often leads to death, usually presents as severe hypotension after TAVI, and should be suspected if migration of the valve occurs. We report the case of a 70-year-old female patient with severe aortic stenosis who underwent TAVI using a 26-mm CoreValve Evolut Pro (Medtronic, Dublin, Ireland). Although the valve was implanted successfully, she experienced hypotension with intermittent ST elevations and had a cardiac arrest shortly after, requiring Advanced Cardiovascular Life Support (ACLS). An aortogram showed sealing of the sinotubular junction (STJ) by CoreValve, without coronary flow. CoreValve was then snared and repositioned in the ascending aorta recovering coronary flow and cardiac pulsatility. A second TAVI was performed and an Edwards 20 mm Sapiens 3 valve (Edwards Lifesciences, Irvine, CA, USA) was implanted as standard procedure.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...